INTERNATIONAL METAL
ENGINEERING |
|
|
|
|
|
|
|
|
INDICATING TEMPERATURE
TRANSMITTER WITH DUAL RELAYS |
|
|
9008PR |
|
|
|
|
|
|
n |
TYPE J / K THERMOCOUPLE
OR RTD INPUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
n |
PANEL MOUNT 1/8 DIN, HIGH
IMPACT PLASTIC |
|
|
|
|
|
|
|
|
|
|
|
n |
NEMA 4 FRONT PANEL |
|
|
|
|
|
|
|
|
|
n |
4 DIGIT 0.5" LED
DISPLAY |
|
|
|
|
|
|
|
|
|
n |
CHOICE OF DEGREES F OR C |
|
|
|
|
|
|
|
|
n |
DUAL RELAYS |
|
|
|
|
|
|
n |
TIME DELAY &
FAIL-SAFE RELAYS |
|
|
|
|
|
|
|
n |
ISOLATED 4 TO 20MA OUTPUT |
|
|
|
|
|
n |
3 YEAR WARRANTY |
|
|
|
|
|
|
|
|
|
Introduction |
|
|
|
|
|
Functional Specifications |
|
|
|
IME Model 9008PR allows 2
independent alarms to be assigned over |
|
Indication Accuracy |
|
|
|
the temperature range of
the sensor. The unit will accept an input from |
|
|
|
|
|
a Pt100 RTD or Type J or
K thermocouple and provide an indication |
|
0.1% of Calibrated range +/- 1 digit |
|
|
|
|
|
on a bright 4 digit LED.
The unit serves a dual purpose since in addition |
|
Set Point Adjustment |
|
|
|
|
to local indication of
temperature, which is switch selectable to read oF |
|
|
|
|
|
or oC, it also serves as an accurate and repeatable temperature
switch. |
|
10~100% of full scale, user selectable |
|
|
|
|
|
|
|
|
Reset |
|
|
|
|
|
|
Automatically when the
input falls below the alarm set point by approximately |
|
|
|
+/- 0.5% of
full scale. |
|
|
|
|
|
|
|
|
Alarm Set Point Accuracy |
|
|
|
|
|
|
|
|
|
|
+/-0.5% of
full scale. |
|
|
|
|
|
|
Description |
|
|
|
|
|
Alarm Status Indication |
|
|
|
The Model 9008PR Life
Saver Series loop indicator accepts the input |
|
|
|
|
|
|
from a Pt100 RTD or type
J or K Thermocouple and displays temperature |
|
LED on front panel |
|
|
|
|
|
|
in degrees F or C. The 4
digit display reads -999 to 9999 in either unit. |
|
Display Height |
|
|
|
All adjustments such as
display, alarm settings, reset values can be |
|
|
|
|
|
|
assigned using membrane
keys or by using a IR remote controller. This |
|
12.5mm (1/2"
|