IME Model 8092 Series Instrument Enclosures are designed to accommodate circuit boards and devices having a maximum
diameter of 92mm(3.6"). Specifically designed for explosion proof applications, the housing is available in either an epoxy
painted Copper-Free Aluminum version or investment casted SS316 to withstand applications where aggressive atmospheres
prevail. The housing can be ordered with either a tempered glass cover or solid cover. There is a wide choice of conduit and
instrument entries.
Order Information
| Model |
Description |
| 8092AN |
General Purpose, 3 Port Aluminum Instrument Enclosure With Blind Cover, Epoxy Coated
|
| 8092AE |
FM (US&Canada) Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port Aluminum Instrument Enclosure With Blind Cover, Epoxy Coated
|
| 8092AT |
ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66, 3 Port Aluminum Instrument Enclosure With Blind Cover, Epoxy Coated
|
| 8092AM |
FM (US&Canada) / ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port Aluminum Instrument Enclosure With Blind Cover, Epoxy Coated |
| 8092WN |
General Purpose, 3 Port Aluminum Instrument Enclosure With Tempered Glass Window, Epoxy Coated
|
| 8092WE |
FM (US&Canada) Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port Aluminum Instrument Enclosure With Tempered Glass Window, Epoxy Coated
|
| 8092WT |
ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66, 3 Port Aluminum Instrument Enclosure With Tempered Glass Window, Epoxy Coated
|
| 8092WM |
FM (US&Canada) / ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port Aluminum Instrument Enclosure With Tempered Glass Window, Epoxy Coated |
| 8092TN |
General Purpose, 3 Port SS316 Instrument Enclosure With Blind Cover, Electro Polished
|
| 8092TE |
FM (US&Canada) Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port SS316 Instrument Housing With Blind Cover, Electro Polished
|
| 8092TT |
ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66, 3 Port SS316 Instrument Housing With Blind Cover, Electro Polished
|
| 8092TM |
FM (US&Canada) / ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port SS316 Instrument Housing With Blind Cover, Electro Polished
|
| 8092SN |
General Purpose, 3 Port SS316 Instrument Enclosure With Tempered Glass Window, Electro Polished
|
| 8092SE |
FM (US&Canada) Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port SS316 Instrument Housing With Tempered Glass Cover, Electro Polished
|
| 8092ST |
ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66, 3 Port SS316 Instrument Housing With Tempered Glass Cover, Electro Polished
|
| 8092SM |
FM (US&Canada) / ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP66/67, T6, 3 Port SS316 Instrument Housing With Tempered Glass Cover, Electro Polished |
| |
Code |
T1 Threads | T2 Threads |
| 04 |
½"NPT |
¾"NPT |
| 05 |
½"NPT |
¾"NPT |
| 06 |
½"NPT |
M20 x 1.5P (See Note 2) |
| 07 |
¾"NPT |
¾"NPT |
| 08 |
¾"NPT |
½"NPT |
| 09 |
¾"NPT |
M20 x 1.5P (See Note 2) |
| 10 |
½"BSP (See Note 1) |
¾"NPT |
| 11 |
½"BSP (See Note 1) |
½"NPT |
| 12 |
½"BSP (See Note 1) |
M20 x 1.5P (See Note 2) |
| 13 |
¾"NPT |
None |
| 14 |
M20 x 1.5P (See Note 2) |
None |
| 16 |
½"BSP (See Note 1) |
None |
| 17 |
½"NPT |
None |
| 18 |
None |
None |
| 19 |
None |
¾"NPT |
| 20 |
None |
½"NPT |
| 21 |
None |
M20 x 1.5P (See Note 2) |
| 8092SE |
08 |
Typical Model Number |
Note:
1. ½"BSP threads are not FM Approved.
2. A temporary metric label is required when an M20 x 1.5P thread is selected. However this thread option is not allowed in Canada.
|
|