International Metal Engineering                
MODEL 8080PA FIELD MOUNTED 2 WIRE PRESSURE TRANSMITTER  
n HIGH ACCURACY 
n 4 : 1 RANGEABILITY
n PRESSURE RANGE OF 0.025 BAR (10" H2O) 
TO 700 BAR (10,000 PSIG)
n 4 DIGIT LED DISPLAY, ENGINEERING UNITS
n CHOICE OF ALUMINUM OR SS316 ENCLOSURE
n EXPLOSION PROOF CERTIFIED
n REMOTE MOUNT SENSOR FROM ENCLOSURE
n 3 YEAR WARRANTY
Introduction      
IME Model 8080PA is a field mounted, 2 wire transmitter with a 4 digit
LED display and a 4 : 1 adjustability. The 8080PA is designed to cover 
a wide range of level and pressure measurement and can be adjusted 
as low as 0.025 Bar (10" H20) and up to a maximum of  700 Bar 
(10,000 PSIG).
Description      
IME Model 8080PA Transmitter is designed for use in process industries
 where vibration, inclement weather and corrosive atmospheres prevail.
The only material that is exposed to the process liquid is SS316. The
Electronics are enclosed in a low copper epoxy coated Aluminum 
housing. For more aggressive environments, a SS316 housing is 
optionally available. The housings meet the requirements of NEMA4X,
and are also certified Explosion Proof by FM. The output current
is linearised and can be set to 4-20mA/ 20-4mA or any range within
these limit. The unit updates 3 times per second for  display and 
4 times per second for the output. The sensor can be remotely mounted
up to 10 meters(30 feet) from the Enclosure.
Functional Specifications   Turn On Time
Process Fluid
     Performs within specification approximately 
     Liquid, Gas and Vapor            2 seconds after power is applied to the transmitter  
Output Signal Temperature Limits
     4-20 mA DC              Process: -50°C to +125°C
Power Supply      Ambient: -50°C to +75°C      
     12 to 45 Vdc         Performance Specifications    
Load Limitation Indication Accuracy
     ± 0.25% Full Scale, includes effects of non- linearity,  
     hysteresis and repeatability      
Stability
     ± 0.2% Full Scale Output for 12 months    
Temperature Effect
     According to: Rmax. (Ω) = (V supply-12) / 0.02  
Zero, Span Adjustment & Configuration      ± 0.02% Full Scale Output per 20º C    
Electrical Connection
      Local Adjustment using Membrane Switches  
Zero Adjustment Limits      1/2"NPT, 3/4"NPT or  M20 x 1.5      
Process Connection 
     1/2"NPT        
Electronic Housing
     IME MODEL 8080 Aluminum/ Stainless Steel Instrument Enclosures
Cover O-Rings
     Buna N          
Identification Plate
     Calibrated Span shall not be less then 0.25URL       Stainless Steel SS304      
     and shall not exceed URL. Mounting
     Low Range Value shall not be below -URL
     Upper Range Value shall not be greater than URL        Wall, Panel or Pipe Mounting      
Indicator
     4 Digit LED indicator      
                             
International Metal Engineering Pte Ltd        http://www.intmet.com